Refine your search:     
Report No.
 - 
Search Results: Records 1-12 displayed on this page of 12
  • 1

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

JAEA Reports

Improvement and mock-up test of vinyl bag for critical experiment fueled with plutonium at STACY (Contract research)

Onodera, Seiji; Sugawara, Susumu; Kobayashi, Heigo; Haga, Koichi; Fukushima, Susumu*; Shichiji,Isamu*; Ono, Akio

JAERI-Tech 2002-070, 77 Pages, 2002/09

JAERI-Tech-2002-070.pdf:8.74MB

no abstracts in English

JAEA Reports

Manufacture of ultrasonic thickness measurement apparatus

Oba, Toshihiro; Yanagihara, Takao; Kato, Chiaki; Hamada, Shozo

JAERI-Tech 2001-059, 36 Pages, 2001/09

JAERI-Tech-2001-059.pdf:7.8MB

The demonstration test for evaluating reliability of the acid recovery evaporator at Rokkasho Reprocessing Plant has been carried out at JAERI. For the nondestructive mesurement of the thickness of heat transfer tubes in the acid recovery evaporator and short tubes used in corrosion test, we have developed ultra sonic thickness measuring apparatus using immersion method with high resolution. This apparatus can measure and record tube thickness automatically with a personal computer. The results obtained by this apparatus are coincident with the results obtained by a destructive method using an optical microscope.

JAEA Reports

Long-term durability test of acid recovery evaporators made of Ti-5% Ta aIloy and zirconium

; Fujisaku, Kazuhiko*; *; ; Koyama, Tomozo

JNC TN8410 2001-013, 255 Pages, 2001/05

JNC-TN8410-2001-013.pdf:24.24MB

Mock-ups of acid recovery evaporators which are made of Ti-5% Ta alloy and Zr were tested under inactive condition for forty thousands hours to improve a corrosion resistance of acid recovery evaporator in Tokai reprocessing plant (TRP). The mock-up unit was designed and produced referring to the specification of acid recovery evaporator in TRP and the evaporation performance of the mock-up was 1/27 of TRP. A long-term durability of both evaporators was demonstrated by results of operation data, evaporation performance and corrosion resistance. The mock-up unit did not suffer from any trouble during the running test and the operation data such as temperature, flow, concentrations of nitric acid and metal ions were fairly stable within standard condition. As for the corrosion resistance, cracks and local corrosion such as intergranular attack were not observed on both evaporators after the running test, and a corrosion of weld was not selective. The average corrosion rates at measuring points were less than 0.1mm/yr, respectively, however, thickness of the Ti-5% Ta alloy evaporator was slightly reduced at all points of vapor phase region. In addition, from the result by test coupon, it is found that both materials have low susceptibility to stress corrosion cracking in this environment. The destructive inspection showed that the mechanical properties of both materials were not degraded during the running test. Finally, the total running time of the mock-up unit is much more than a maximum running time of acid recovery evaporator made of stainless steel in TRP (nearly 15,000 hours). On the basis of the test results, an excellent durability of Ti-5% Ta alloy and Zr evaporators under was successfully demonstrated throughout the mock-up test from an engineering perspective.

JAEA Reports

Mock-up test of remote controlled dismantling apparatus for large-sized vessels (Contract research)

Myodo, Masato; Okane, Shogo; Miyajima, Kazutoshi

JAERI-Tech 2001-025, 59 Pages, 2001/03

JAERI-Tech-2001-025.pdf:4.73MB

no abstracts in English

JAEA Reports

None

; ; Ishibashi, Yuzo; Takeda, Seiichiro; *; Fujisaku, Kazuhiko*; *

PNC TN8410 98-116, 147 Pages, 1998/08

PNC-TN8410-98-116.pdf:8.42MB

None

JAEA Reports

Mockup test apparatus for the inspection system of steam generator tubes; Design and Manufacturing

; ; ; ;

PNC TN9410 92-254, 76 Pages, 1992/07

PNC-TN9410-92-254.pdf:2.02MB

A verification test of the inspection system of Monju steam generator(SG) tubes will be performed in near future. Mockup Test Apparatus for the inspection system of SG tubes was manufactured and installed at Mechatronics Application Reserch Facility (MARF) in OEC. The test apparatus has the same specification, which is prepared for verification test, as Monju plant; for instance, which are dimension and material of tubes, and workability for the inspection equipment. About one hundred and forty SG tubes are radially arranged in tube sheets in Monju SG, however, three tubes, inner, center and outer one, are sellected in this test apparatus for testing of inspection system, It was verified that the test apparatus was manufactured with the same accuracy and dimension as Monju. System verification test is planned using this test apparatus.

JAEA Reports

None

; ; ; ; ; ; Otaka, Masahiko

PNC TN9410 92-218, 103 Pages, 1992/04

PNC-TN9410-92-218.pdf:3.49MB

None

JAEA Reports

Reports of results of mock-up test concerning the remote piping work system

Tanaka, Yoji*; Nakasawa, Otohiko*; Sugumoto, Hiroshi*; Takeshita, Hiroshi*

PNC TJ8224 92-002, 33 Pages, 1992/03

PNC-TJ8224-92-002.pdf:1.06MB

no abstracts in English

JAEA Reports

Reports of results of mock-up test concerning the remote piping work system

Tanaka, Yoji*; Nakasawa, Otohiko*; Sugumoto, Hiroshi*; Takeshita, Hiroshi*

PNC TJ8224 92-001, 108 Pages, 1992/03

PNC-TJ8224-92-001.pdf:3.29MB

no abstracts in English

JAEA Reports

Mock-up Tests for a Hot Vitrification System

; *; ; ; ; ; ; ; *; *; et al.

JAERI-M 9192, 33 Pages, 1980/11

JAERI-M-9192.pdf:1.78MB

no abstracts in English

Oral presentation

Construction of remote-control equipment and device development facility

Kawamura, Hiroshi

no journal, , 

no abstracts in English

12 (Records 1-12 displayed on this page)
  • 1